Skip to main content Skip to secondary navigation
Momei Zhou : varicella-zoster virus replication in human melanoma cells.

Light Microscopes

Main content start

Instruments

Leica Stellaris8 DIVE upright Confocal, multi-photon

Inverted, laser scanning confocal microscope for imaging from the UV to the near IR, Fluorescence-lifetime, and 2-photon.

  •  Point scanning confocal with up to 5 sumultaneous detection channels, from 410 to 850 nm
  • Environmental control for live cell imaging (temperature and CO2)
  • Excitation and emission wavelength scanning
  • Fluorescence lifetime imaging (FLIM)
  • Deconvolution for super resolution
  • Pulsed infrared laser for 2-photon and Second Harmonic Generation (SHG) imaging
  • Förster Resonance Energy Transfer (FRET) by intensity or lifetime methods
  • Photobleaching/photoablation (FRAP)
  • Multiwell plate imaging

Required acknowledgements: 

Please cite “Stanford University Cell Sciences Imaging Core Facility (RRID:SCR_017787)” and state “The Leica Stellaris confocal was purchased with funding from Stanford University Community of Shared Advanced Research Platforms (C-ShaRP) (RRID:SCR_022986)"

Reserve this microscope>

Location: Beckman Center, Room B050


Zeiss Elyra7 Lattice SIM super resolution with widefield "apotome" 

  • Live Cell Imaging
  • STORM, TIRF, Lattice SIM, SIM, Widefield apotome, leap, burst mode
  • 10x, 20x, 25x, 40x, 63x/1.4, 63x/1.46
  • Required Acknowledgement:The following acknowledgement is required when publishing data obtained with this instrument: "The project described was supported, in part, by Award Number 1S10OD034400-01A1 from the S10 Instrumentation Programs. Its contents are solely the responsibility of the authors and do not necessarily represent the official views of the S10 Instrumentation Programs or the National Institutes of Health."

Reserve this microscope>

Location: Beckman Center, Room B050A


Inverted Zeiss LSM 880 Laser Scanning Confocal Microscope

  • Laser scanning confocal
  • Live Cell Imaging support with heating stage and CO2
  • Imaging of weak fluorescence signals with high sensitivity AirScan mode
  • Super Resolution imagining with AiryScan (1.7X improvement over diffraction limited imaging)
  • FAST AiryScan (acquisition speeds of 27fps (at 480 x 480 pixels))
  • FRET, FRAP and FLIP
  • Photoactivation/ -conversion
  • Photon Counting

Reserve this microscope>

Location: Beckman Center, Room B050


Leica SP8 inverted Confocal with WLL

  • Supercontinuum White light laser 470-670nm, up to 8 lines
  • 3x gated, hybrid detectors, 2x PMT
  • Spectral Imaging, Unmixing
  • Excitation Fingerprinting
  • Live Cell Imaging
  • Ultra-fast resonant scanner(8000Hz=30ms bidirectional for 512line frame)
  • FRAP/FLIP/FRET
  • Transmittance detection/DIC/Phase
  • Detector upgraded for 2x scan speed than standard SP8

 

Reserve this microscope

Location: Beckman Center, Room B050C


Leica Stellaris Scanning Confocal/FLIM/2-photon microscope

Inverted, laser scanning confocal microscope for imaging from the UV to the near IR, Fluorescence-lifetime, and 2-photon.

  • Point scanning confocal with up to 5 sumultaneous detection channels, from 410 to 850 nm
  • Environmental control for live cell imaging (temperature and CO2)
  • Excitation and emission wavelength scanning
  • Fluorescence lifetime imaging (FLIM)
  • Deconvolution for super resolution
  • Pulsed infrared laser for 2-photon and Second Harmonic Generation (SHG) imaging
  • Förster Resonance Energy Transfer (FRET) by intensity or lifetime methods
  • Photobleaching/photoablation (FRAP)
  • Multiwell plate imaging

Required acknowledgements: 

Please cite “Stanford University Cell Sciences Imaging Core Facility  (RRID:SCR_017787)” and state “The Leica Stellaris confocal was purchased with funding from Stanford University Community of Shared Advanced Research Platforms (C-ShaRP) (RRID:SCR_022986)"

Reserve this microscope

Location: Cell Sciences Imaging Facility, Shriram Center 023


Inverted Nikon Crest V3 Spinning Disk Confocal Microscope

  • Live Cell Imaging
  • Fast Confocal Imaging (1000 frames per second possible)
  • High Content Screening and Throughput
  • TIRF (to image events at the cell surface ~100nm)
  • Large Field of View for WideField Imaging (>3200x3200, 6.5 um pixel)
  • Possibly to do near infrared excitation (730nm)
  • FRET

 

Reserve this microscope

Location: Shriram Center, Room B023


Zeiss LSM900 Inverted Confocal Microscope with AiryScan2 microscope

  • Laser scanning confocal
  • Live Cell Imaging
  • Super Resolution imagining with AirScan2 (32-channel detector) - delivers enhanced sensitivity and super-resolution imaging beyond conventional confocal, with faster acquisition and reduced phototoxicity.)
  •  

Reserve this microscope

Location: Shriram Center, Room B023


Bruker Truelive Light Sheet Microscope

Lightsheet microscope for time-lapse fluorescence volumetric imaging of embryos and tissues.

  • Three objective lightsheet microscope with dual sided illumination and a single imaging objective
  • Dual cameras for simultaneous imaging
  • Six laser lines
  • Environmental control for live sample imaging (temperature, humidity, and CO2)
  • Gentle illumination for minimal photobleaching and phototoxicity over extended time-lapse
  • Photomanipulation system for photostimulation, ablation, or bleaching
  • Custom V-shaped imaging chambers for samples up to 300 µm thick

Reserve this microscope

Location: Shriram Center, Room B023


ZEISS Lattice Light Sheet 7 Microscope

Lightsheet microscope for time-lapse fluorescence volumetric imaging of live cells and tissues with subcellular resolution.

  • Structured illumination to generate thinner light sheets for improved resolution
  • Up to three fluorescence channels
  • Environmental control for live cell imaging (temperature, humidity, and CO2)
  • Gentle illumination for minimal photobleaching and phototoxicity over extended time-lapse
  • Deconvolution for super resolution
  • Stage inserts for Dish, slide, or multiwell plate
  • Custom-built perfusion system availableLong-term volumetric imaging of living cells
  • Fast live cell imaging at subcellular resolution
  • Uses standard sample carriers.

Reserve this microscope

Location: Shriram Center, Room B023


Nikon Ti-2e inverted widefield microscope

  • Plan Apo 4x/0.20 WD=20mm dry lens
  • Plan Apo 20x/0.8 WD=0.8mm dry lens
  • Plan Apo 40x/0.95 WD=0.25-0.17 dry lens
  • Plan Apo 60x/1.42 WD=0.15 oil lens
  • Sola light source
  • Photometrics Iris15 camera(15Megapixel, 25mm Field of View, 30 Frames/s, 73% QE)
  • Filters: Dapi, Cy3, Cy5, mCherry, Cy7, Brightfield
  •  Filter Cubes:EX (nm) EM (nm) Dichroic
    DAPI341-371356/30417-477447/60409
    GFP/FITC/CY2446-486466/40500-550525/50495
    CY3/TRITC532.5-557.5545/25570-640605/70565
    TR/mCherry542-582562/40603.5-678.5641/75593
    Cy5626-644635/18659-701680/42652
    CY7670.5-745.5708/75768.5-849.5809/81757
  • slide stitching/ scanning and NIS-Elements AR batch JOBS module along with AR analysis module.

Reserve this microscope>

Location: Beckman Center, Room B050C


Leica DM2000 histology scope with color cameras

microscope
  • Color camera
  • Histology

Reserve this microscope

Location: Beckman Center, Room B001